| Product Description |
|---|
| Single head system |
| General specifications | ||
|---|---|---|
| Sensing range | 30 ... 500 mm | |
| Adjustment range | 50 ... 500 mm | |
| Dead band | 0 ... 30 mm | |
| Standard target plate | 100 mm x 100 mm | |
| Transducer frequency | approx. 380 kHz | |
| Response delay | approx. 50 ms | |
| Indicators/operating means | ||
| LED yellow | solid yellow: object in the evaluation range yellow, flashing: program function, object detected |
|
| LED red | solid red: Error red, flashing: program function, object not detected |
|
| Electrical specifications | ||
| Operating voltage | 15 ... 30 V DC , ripple10%SS | |
| No-load supply current | ï 50 mA | |
| Input/Output | ||
| Synchronization | 1 synchronous connection, bi-directional 0-level: -UB...+1 V 1-level: +4 V...+UB input impedance: > 12 kï synchronization pulse: ï 100 ïs, synchronization interpulse period: ï 2 ms |
|
| Synchronization frequency | ||
| Common mode operation | max. 95 Hz | |
| Multiplex operation | ï 95 Hz / n, n = number of sensors, n ï 5 | |
| Input | ||
| Input type | 1 program input lower evaluation limit A1: -UB... +1 V, upper evaluation limit A2: +4 V ... +UB input impedance: > 4.7 kï, pulse duration: ï 1 s |
|
| Output | ||
| Output type | 1 analog output 0 ... 10 V | |
| Resolution | 0.11 mm at max. sensing range | |
| Deviation of the characteristic curve | ï 1 % of full-scale value | |
| Repeat accuracy | ï 0.1 % of full-scale value | |
| Load impedance | > 1 kOhm | |
| Temperature influence | ï 1.5 % of full-scale value | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 EN 60947-5-7:2003 IEC 60947-5-7:2003 |
|
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated ï36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 C (-13 ... 158 F) | |
| Storage temperature | -40 ... 85 C (-40 ... 185 F) | |
| Mechanical specifications | ||
| Connection type | Connector plug M12 x 1 , 5-pin | |
| Degree of protection | IP67 | |
| Material | ||
| Housing | brass, nickel-plated | |
| Transducer | epoxy resin/hollow glass sphere mixture; foam polyurethane, cover PBT | |
| Mass | 60 g | |
| Dimensions | ||
| Length | 85 mm | |
| Diameter | 18 mm | |
| Factory settings | ||
| Output | evaluation limit A1: 50 mm evaluation limit A2: 500 mm output function: rising ramp |
|
| Beam width | wide |
|